Regional Availability | Australia/New Zealand | Latin America | North America | Asia | EMEA |
Portfolio | Blrand® |
Product Type | Fiber indoor cable |
Cable Type | Distribution |
Construction Type | Non-armored |
Fiber Type, quantity | 12 |
Jacket Color | Black |
Subunit Type | Gel-free |
Total Fiber Count | 12 |
Diameter Over Jacket | 5.95 mm | 0.234 in |
Minimum Bend Radius, loaded | 89 mm | 3.504 in |
Minimum Bend Radius, unloaded | 59 mm | 2.323 in |
Tensile Load, long term, maximum | 200 N | 44.962 lbf |
Tensile Load, short term, maximum | 667 N | 149.948 lbf |
Compression | 10 N/mm | 1.751 lb/in |
Compression Test Method | IEC 60794-1 E3 | FOTP-41 |
Flex | 100 cycles |
Flex Test Method | IEC 60794-1 E6 | FOTP-104 |
Impact | 5.88 N-m | 52.042 in lb |
Impact Test Method | FOTP-25 | IEC 60794-1 E4 |
Strain | See long and short term tensile loads |
Strain Test Method | FOTP-33 | IEC 60794-1 E1 |
Twist | 10 cycles |
Twist Test Method | FOTP-85 | IEC 60794-1 E7 |
Vertical Rise, maximum | 500 m | 1640.42 ft |
Fiber Type | OM3, LazrSPEED® 300 | OM3, LazrSPEED® 300 |
Installation temperature | -20 °C to +70 °C (-4 °F to +158 °F) |
Operating Temperature | -20 °C to +70 °C (-4 °F to +158 °F) |
Storage Temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
Cable Qualification Standards | Telcordia GR-409 | ANSI/ICEA S-83-596 |
Environmental Space | Riser |
Flame Test Listing | NEC OFNR (ETL) and c(ETL) |
Flame Test Method | UL 1666 |
Heat Age | -20 °C to +85 °C (-4 °F to +185 °F) |
Heat Age Test Method | IEC 60794-1 F9 |
Low High Bend | -20 °C to +70 °C (-4 °F to +158 °F) |
Low High Bend Test Method | FOTP-37 | IEC 60794-1 E11 |
Temperature Cycle | -20 °C to +70 °C (-4 °F to +158 °F) |
Temperature Cycle Test Method | FOTP-3 | IEC 60794-1 F1 |
Cable weight | 32 kg/km | 231.456 lb/kft |